login

Search documents

Browse topics

Document details

 
Title:
 
Carrier Lifetime Measurements of Monocrystalline Silicon Ingots Using Upgraded Laser E-PCD Technique
 
Author(s):
 
D. Krisztian, F. Korsós, I. Saegh, G. Paráda, P. Tüttö, X. Dong, H. Deng, S. Wang, X. Chen
 
Keywords:
 
Lifetime, Recombination, Monocrystalline, Silicon, Ingot
 
Topic:
 
Silicon Materials and Cells
Subtopic: Feedstock, Crystallisation, Wafering, Defect Engineering
Event: 38th European Photovoltaic Solar Energy Conference and Exhibition
Session: 2DO.10.6
 
Pages:
 
194 - 197
ISBN: 3-936338-78-7
Paper DOI: 10.4229/EUPVSEC20212021-2DO.10.6
 
Price:
 
 
0,00 EUR
 
Document(s): paper
 

Abstract/Summary:


The photoconductance decay (PCD) method is a standard characterization technique for carrier lifetime characterization of silicon ingots. We analyzed the precision of the eddy current PCD technique using monochromatic light focusing on the impact of the properties of the laser excitation. The PCD measurement simulations showed that the impact of the surface recombination in the measured lifetime and the injection level is highly influenced by the wavelength and the pulse duration of the laser excitation source. Considering the time evolution of carrier profile as well, an optimal wavelength range between 1050 and 1070 nm has been found. The eddy-current detected PCD (e-PCD) measurements using the original 980 nm and a rather optimal 1064 nm laser was compared experimentally and by simulation in details. In the injection independent lifetime model, the effective lifetime approaches the bulk lifetime asymptotically within a reasonable time, and both laser source provides accurate result as experimentally confirmed. However, if carrier lifetime varies significantly with injection level, a pronounced difference between the asymptotic lifetimes recorded using the different lasers is observed. Lifetime values from the longer wavelength setup approach the saturation value of bulk lifetime even in this case. This is an additional important advantage of using the longer wavelength laser for ingot PCD measurements. Comparing the laser e-PCD results to flash lamp based PCD systems, a good correlation is found in the long lifetime regime. However, the significant discrepancies found between transient and Quasi-Steady-State (QSS) modes of the flash lamp PCD system indicate that performing the measurement in transient mode for the entire lifetime range is very beneficial, which is realized using the laser based PCD method.